CTRLB9012F

SERIES CTRLB9012F

Results: 51

Img Part Information Series Inductance Current DCR Mount Type Lead Type Shielding Tolerance Operating Temp. Inductor Type SRF Q

Part No.: CTRLB9012F-822K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 8 uH 0.18 mA 22.7 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.35 MHz 15

Part No.: CTRLB9012F-821K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 820 uH 0.56 mA 1.8 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 1.5 MHz 20

Part No.: CTRLB9012F-820K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 82 uH 1.3 mA 0.23 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 4.1 MHz 30

Part No.: CTRLB9012F-6R8K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 6.8 uH 4.1 mA 0.035 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 29 MHz 20

Part No.: CTRLB9012F-682K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 6 uH 0.2 mA 20.7 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.4 MHz 15

Part No.: CTRLB9012F-681K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 680 uH 0.59 mA 1.6 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 1.6 MHz 20

Part No.: CTRLB9012F-680K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 68 uH 1.36 mA 0.21 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 4.9 MHz 30

Part No.: CTRLB9012F-562K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 5 uH 0.22 mA 14.9 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.45 MHz 15

Part No.: CTRLB9012F-561K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 560 uH 0.64 mA 1.4 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 1.8 MHz 20

Part No.: CTRLB9012F-560K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 56 uH 1.48 mA 0.18 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 5.4 MHz 30

Part No.: CTRLB9012F-4R7M RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 4.7 uH 4.6 mA 0.03 Ω Through Hole Radial Unshielded ±20% -55°C to +125°C 51 MHz 20

Part No.: CTRLB9012F-473K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 47 uH 0.08 mA 137.8 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.12 MHz 15

Part No.: CTRLB9012F-472K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 4 uH 0.24 mA 13.6 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.5 MHz 15

Part No.: CTRLB9012F-471K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 470 uH 0.68 mA 1.1 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 1.9 MHz 20

Part No.: CTRLB9012F-470K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 47 uH 1.77 mA 0.16 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 6.5 MHz 30

Part No.: CTRLB9012F-3R3M RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 3.3 uH 5.5 mA 0.025 Ω Through Hole Radial Unshielded ±20% -55°C to +125°C 65 MHz 20

Part No.: CTRLB9012F-393K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 39 uH 0.08 mA 125.5 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.15 MHz 15

Part No.: CTRLB9012F-392K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 3 uH 0.27 mA 9.9 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.55 MHz 15

Part No.: CTRLB9012F-391K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 390 uH 0.74 mA 1 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 2.1 MHz 20

Part No.: CTRLB9012F-390K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 39 uH 1.85 mA 0.1 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 6.9 MHz 30

Part No.: CTRLB9012F-333K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 33 uH 0.09 mA 91.5 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.17 MHz 15

Part No.: CTRLB9012F-332K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 3 uH 0.29 mA 9.1 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 0.6 MHz 15

Part No.: CTRLB9012F-331K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 330 uH 0.78 mA 0.85 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 2.3 MHz 20

Part No.: CTRLB9012F-330K RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 33 uH 2.05 mA 0.09 Ω Through Hole Radial Unshielded ±10% -55°C to +125°C 7.8 MHz 30

Part No.: CTRLB9012F-2R2M RoHS Compliant

Mfr: CENTRAL TECHNOLOGIES

Desc: Radial Leaded Fixed Inductor Peaking Coil

CTRLB9012F 2.2 uH 6.5 mA 0.021 Ω Through Hole Radial Unshielded ±20% -55°C to +125°C 90 MHz 20